DF2000 control valves are post guided, single port valves used for high pressure/high temperature lower flow applications. These heavy-duty globe and angle style valves perfect for general service or severe service applications.
AVAILABLE CONFIGURATIONS | ||||||||
BODY | BODY SIZE | END CONNECTION | PRESSURE RATING | |||||
ASME CLASS 150 | ASME CLASS 300 | ASME CLASS 600 | ASME CLASS 900/1500 | ASME CLASS 1500 | ASME CLASS 2500 | |||
GLOBE | 1" NPS (25mm DN) | NPT | û | û | û | û | ü | û |
RF | ü | ü | ü | ü | û | û | ||
RTJ | û | ü | ü | ü | û | û | ||
2" NPS (50mm DN) 3X2" NPS (80X50mm DN) 4X2" NPS (100X50mm DN) | NPT | û | û | û | û | ü | ü | |
RF | ü | ü | ü | ü | û | ü | ||
RTJ | û | û | ü | ü | û | ü | ||
ANGLE | 1" NPS (25mm DN) | NPT | û | û | û | û | ü | û |
RF | û | ü | ü | ü | û | û | ||
RTJ | û | ü | ü | ü | û | û | ||
2" NPS (50mm DN) | NPT | û | û | û | û | ü | ü | |
RF | û | ü | ü | ü | û | ü | ||
RTJ | û | ü | ü | ü | û | ü |
AVAILABLE SHUTOFF CLASSIFICATION | |||
VALVE TRIM | VALVE SIZE | SHUTOFF CLASS | |
ALL | ALL | STANDARD | CLASS IV |
OPTIONAL | CLASS V |
CHARACTERISTIC | PREFERRED FLOW DIRECTION |
DYNA-FORM (EQUAL PERCENTAGE) | FLOW UP |
DYNA-FLUTE 1 FLUTE (EQUAL PERCENTAGE) | FLOW UP |
DYNA-FLUTE 3 FLUTE (EQUAL PERCENTAGE) | FLOW UP |